8.14.2 Fitting and connecting the sewing lamp transformer

Danger to life due to electric shock.
The sewing lamp transformer is connected directly
to the power supply.
If you disconnect the sewing machine from the
power supply at the main switch, the sewing lamp
transformer is still live.
Disconnect the power plug before fitting and con-
necting the sewing lamp transformer.
Figure 46: Fitting the sewing lamp transformer
• Screw the sewing lamp transformer (1) in place at the pre-drilled
holes (2) under the table plate.
• Fasten the connecting cable under the table plate using cable ties.
• Establish the plug connection to the supply line for the sewing lamp.
(4)
(3)
(3)
(1) - X3 port
(2) - 24V/X5 port
Figure 47: Connecting the sewing lamp transformer to the control
• Loosen the screw holder (4) for the control until the control can be
removed.
• Remove the control.
• Loosen the screws (3) on the control cover.
• Connect the supply line:
For additional sewing lamps to be fitted: to the X3 port (1)
For integrated LED sewing lamps: to the 24V/X5 port (2)
42
DANGER
q
(1) - Sewing lamp transformer
(2) - Pre-drilled holes
w
(3) - Screws on the control cover
(4) - Screw holder