5.1.1
Sewing lamp transformer connection to network voltage
18
Caution! Risk of electric current injury!
The sewing lamp transformer is not switched off by the main switch
(EN 60 204-31)! At the sewing lamp installation and repair inside the
transformer box, e.g. at a fuse replacement, the mains plug must be
disconnected from the power outlet.
A. The machine is equipped with the following drives:
FIR 1147 - F554.3
FIR 1148 - F752.3
Pull the mains plug from the power outlet.
Conduct the transformer cable to the main switch.
Connect the transformer cable according to the wiring schedule,
which is included in the delivery of the set of parts supplied with
the machine head.
Stick a self-sticking label with safety instructions on the front side
of the main switch.
B. The machine is equipped with the Efka DC1550/DA321G drive
2
6
5
1
Pull the mains plug from the power outlet.
Screw out 4 screws on the front panel of the control box.
Dismantle the front panel.
Pull the transformer cable through the channel (1) in the control
box.
Remove the black rubber bushing (2).
Pierce the bushing with a screwdriver.
Pull the sewing lamp transformer cable through the arisen hole.
Insert the rubber bushing back again.
Press the clip openers (3) and (4) with a small screwdriver slightly
until the clips (5) and (6) open.
Connect the blue conductor to the terminal (6) and the brown
conductor to the terminal (5).
Screw the front panel back again.
Fix the light transformer cable against pulling off (e.g. with a
fastening band to a supply mains cable).
6
5
4
3