• MSW 1-5: CR Code Processing
Function: Selects whether the printer operates in the same manner as LF (<0A>H) when it
receives the CR(<0D>H) code.
CR mode
Operation at ON (1):
Operates in the same manner as LF when receiving CR code.
Prints data in the print buffer and performs line feed in accordance with the amount of
preset line feed.
Operation at OFF (0):
Even when the printer receives a CR code, it ignores CR code and causes no operation.
• MSW1-6: Omitted for reservation.
• MSW 1-7: Reset Valid/Invalid by DSR (Serial I/F 6 Pin)
Function: Selects whether to reset the printer by the signal of DSR (Serial interface 6 Pin).
DSR Signal
Operation at ON (1):
Used as Reset signal.
Operation at OFF (0):
Not used as Reset signal.
• MSW 1-8: Valid/Invalid of Reset by the Reset signal of INIT (Serial I/F 25 pin)
Function: Selects whether to reset the printer by the INIT (Serial I/F 25 Pin) signal.
INIT Signal
Operation at ON (1):
Used as a Reset signal.
Operation at OFF (0):
Not used as Reset signal.
OFF (0)
ON (1))
Ignored
OFF(0)
ON(1)
Invalid
Valid
OFF(0)
ON(1)
Invalid
Valid