CHAPTER 3
6. Operation panel
1) Remove the top cover unit.
2) Unhook the 2 claws, and then remove
the flat cable from the operation panel.
Claws
Operation panel
Figure 3-2-10
<Note for reassembly>
When installing the operation panel, be
sure to set the flat cable securely.