Canon LBP-1000 Service Manual page 90

Hide thumbs Also See for LBP-1000:
Table of Contents

Advertisement

1. Rear cover
1) Remove the cassette.
2) Open the face-up tray to its horizontal
position by holding the both sides of the
tray with the both hands.
3) Remove the 2 screws and unhook the 3
claws, and then remove the rear cover
with the face-up tray.
4) Pull out the expansion tray.
5) While pushing the right side of the rear
cover to bend it, take out the face-up
tray shaft to remove the face-up tray
unit from the rear cover.
Screws
Claws
Expansion tray
Face-up tray unit
Rear cover
Figure 3-2-2
2. Top cover unit
1) Open the multi-purpose tray.
2) Remove the rear cover.
3) Remove the 2 screws.
Screws
Figure 3-2-3
Note:
The operation panel on the top
cover is attached with the connec-
tor PCB and flat cable.
In the procedure 5 stated in the fol-
lowing page, if the top cover swing
opens, the flat cable may be dam-
aged, so when removing the top
cover, slightly lift it and then gently
hold the flat cable.
CHAPTER 3
3 - 3

Advertisement

Table of Contents