Brady PAM 3600 Service Manual page 38

Printer applicator system
Hide thumbs Also See for PAM 3600:
Table of Contents

Advertisement

4 Replacing Assembly Units
Figure 4n Connectors at the CPU PCB
6 Label edge sensor
7 Low-voltage input from power pack
8 Printhead logic connector
9 Control panel
10 Transfer ribbon sensor
11 Applicator control PCB
12 Applicator control PCB (alternative)
13 Sensor transport locking roller
14 Motor
Mounting the CPU PCB:
12. Attach the PCB and secure it with four screws M4x10 (1).
13. Insert all plugs (see figure 4n).
14. Reinstall the cable across the CPU PCB (3).
15. Reassemble the cover.
16. Reinstall the power supply connector and the connectors for the peripheral interfaces, your optional interface
card inclusive.
17. If necessary carry out a firmware update.
18. Adjust the label edge sensor (see section 5.8).
19. Perform the needful adjustments in the Printer Configuration.
8
05/N31
G-TESTED
SUPPLY
POMER
SENSOR
GAP
6
7
9
10
11
12
13
14
PRINTHEAD
8
Service Manual PAM 3600