Printing Parameters - Brady BP-PR 300 PLUS Series User Manual

Bp-pr plus series
Table of Contents

Advertisement

BP-PR PLUS Series

4-1-3 Printing Parameters

1. Press the menu button.
2. Select Setup > Print param.
Parameter
Heat Level
Print Speed
Transfer Print
Warn Level
Ribbon
Label Sensor
Tear-off Mode
Edition 06/10
Heating value for compensating for differing thermal behavior of
print-heads. Changing this value is then necessary if printing
intensity has changed after replacing printhead. To adapt printing
intensity when using different media, print speeds or printing
contents, you should change the heat level in the software. The
settings from the Print param. menu and the software are added
together. The heat level setting also affects the test printouts.
Basic print speed setting. You can re-specify the print speed for
each print job via software. The basic setting is not changed by
this. The print speed setting also affects the test printouts.
On for thermal transfer printing: Sensor for monitoring the transfer
ribbon is activated. Off for thermal direct printing: Sensor for
monitoring the transfer ribbon is not activated. You can overwrite
the setting for each print job via software.
Warning via the Ethernet interface by way of an SNMP message
or e-mail sent when the remaining diameter of the ribbon supply
roll undershoots the set value (32–74 mm).
Method for detecting the starting end of the label. Gap Sensor:
Detection using changes in the transparency between the label
and label gap. Bottom-Reflect: Detection using reflex marks on
the bottom of the medium. Continous media: Synchronization of
the paper flow when using endless media in cutting mode. More
detailed information is found in the documentation of the cutter.
Positioning the label medium for tearing off at the tear-off plate.
On: Additional advancement of the label medium which positions
the label gap after the last printed label at the dispense plate.
Off: Label advance stops once the last label has fully passed the
print line.
User Manual
Meaning
Default
0
100 mm/s
On
Off
GapSensor
Off
19