 Error and Warning Information
An E-
indication may appear in the upper right corner of the screen to notify errors not related to copying
or formatting.
Indication
No
30
Indicates that an error occurred during P2 card or storage device access.
To continue operation, turn the power off and then back on again.
37
Displayed when a system controller command was not observed.
To continue operation, turn the power off and then back on again.
38
Displayed when a communications error occurs.
To continue operation, turn the power off and then back on again.
50
Displayed when a drop in the backup battery voltage for the internal clock is
detected at power on.
Charge the internal battery.
45).
BA
The battery is depleted.
Charge the battery.
70
Indicates that the directory structure of the P2 card is not supported.
Immediately make a backup of card data and reformat the card.
71
Indicates that the maximum number of overwrites for the P2 card has been
reached.
This P2 card should be replaced.

Description
 For details, refer to "Internal Battery" (page
Operation
STOP
STOP
STOP
Operation
continues
The unit is
shut down.
Operation
continues
Operation
continues