Item
Automatic Timer
Elevation
Auto Focus System
Reliability
Maintenance
Warranty
7-PIN REMOTE CONTROL
(See illustration on next page.)
REMOTE INLET
SM5440-1 – 18NOV97
Operates between the following times:
• Fast = 3 1 second
• Slow = 22 6 seconds
14 maximum front elevation assembly.
• After the initial focus adjustment, the auto-
focus system will adjust for the difference in
the slide position from slide to slide. This
focus adjustment will occur within 1 second
after the slide is inserted into the GATE.
• The focus adjustment variation should not
change from the focus and reverse
specifications by more than 3 times the
focus and reverse specifications.
The projector can operate for 2000 hours or
2,000,000 cycles. The projector has a MTBF
(mean time between failures) of 7500 operation
hours.
Preventive maintenance by a qualified service
person is recommended every 1500 hours of
operation, or after 1 year.
See the owner's manual.
• PIN 1 - Black, REMOTE FOCUS
• PIN 2 - Green, FORWARD TRAY CYCLE
• PIN 3 - Orange, REVERSE TRAY CYCLE
• PIN 4 - Brown, RACK SOLENOID
• PIN 5 - Yellow, COMMON
• PIN 6 - Brown, LAMP CONTROL
• PIN 7 - White, LAMP CONTROL
24 V AC
24 V AC
N
K
4
1
5
Y
2
3
G
O
0 V AC
24 V AC
Common
A100_0023ACA
A100_0023AA
Desription
7-PIN PLUG
7
W
82 V AC
Unloaded
6
N
Specifications