Understanding How Environmental Monitoring Works; Monitoring System Environmental Status - Cisco 7604 Configuration Manual

Ios software configuration guide
Hide thumbs Also See for 7604:
Table of Contents

Advertisement

Understanding How Environmental Monitoring Works

Understanding How Environmental Monitoring Works
Environmental monitoring of chassis components provides early-warning indications of possible
component failures, which ensures a safe and reliable system operation and avoids network
interruptions. This section describes the monitoring of these critical system components, which allows
you to identify and rapidly correct hardware-related problems in your system.

Monitoring System Environmental Status

To display system status information, enter the show environment [alarm | cooling | status |
temperature] command. The keywords display the following information:
To view the system status information, enter the show environment command:
Router# show environment
environmental alarms:
no alarms
Router# show environment alarm
environmental alarms:
no alarms
Router# show environment cooling
fan-tray 1:
fan-tray 1 fan-fail: failed
fan-tray 2:
fan 2 type: FAN-MOD-9
fan-tray 2 fan-fail: OK
chassis cooling capacity: 690 cfm
ambient temperature: 55C
chassis per slot cooling capacity: 75 cfm
module 1 cooling requirement: 70 cfm
module 2 cooling requirement: 70 cfm
module 5 cooling requirement: 30 cfm
module 6 cooling requirement: 70 cfm
module 8 cooling requirement: 70 cfm
module 9 cooling requirement: 30 cfm
Router# show environment status
backplane:
operating clock count: 2
operating VTT count: 3
fan-tray 1:
fan-tray 1 type: WS-9SLOT-FAN
fan-tray 1 fan-fail: OK
VTT 1:
Cisco 7600 Series Router Cisco IOS Software Configuration Guide, Release 12.2SX
54-10
alarm—Displays environmental alarms.
status—Displays alarm status.
thresholds—Displays alarm thresholds.
cooling—Displays fan tray status, chassis cooling capacity, ambient temperature, and per-slot
cooling capacity.
status—Displays field-replaceable unit (FRU) operational status and power and temperature
information.
temperature—Displays FRU temperature information.
Chapter 54
Power Management and Environmental Monitoring
["40C (user-specified)" if temp-controlled]