Cisco 7604 Configuration Manual page 919

Ios software configuration guide
Hide thumbs Also See for 7604:
Table of Contents

Advertisement

Chapter 54
Power Management and Environmental Monitoring
environmental alarm thresholds:
power-supply 1 fan-fail: OK
threshold #1 for power-supply 1 fan-fail:
(sensor value != 0) is system minor alarm power-supply 1 power-output-fail: OK
threshold #1 for power-supply 1 power-output-fail:
(sensor value != 0) is system minor alarm fantray fan operation sensor: OK
threshold #1 for fantray fan operation sensor:
(sensor value != 0) is system minor alarm operating clock count: 2
threshold #1 for operating clock count:
(sensor value < 2) is system minor alarm
threshold #2 for operating clock count:
(sensor value < 1) is system major alarm operating VTT count: 3
threshold #1 for operating VTT count:
(sensor value < 3) is system minor alarm
threshold #2 for operating VTT count:
(sensor value < 2) is system major alarm VTT 1 OK: OK
threshold #1 for VTT 1 OK:
(sensor value != 0) is system minor alarm VTT 2 OK: OK
threshold #1 for VTT 2 OK:
(sensor value != 0) is system minor alarm VTT 3 OK: OK
threshold #1 for VTT 3 OK:
(sensor value != 0) is system minor alarm clock 1 OK: OK
threshold #1 for clock 1 OK:
(sensor value != 0) is system minor alarm clock 2 OK: OK
threshold #1 for clock 2 OK:
(sensor value != 0) is system minor alarm module 1 power-output-fail: OK
threshold #1 for module 1 power-output-fail:
(sensor value != 0) is system major alarm module 1 outlet temperature: 21C
threshold #1 for module 1 outlet temperature:
(sensor value > 60) is system minor alarm
threshold #2 for module 1 outlet temperature:
(sensor value > 70) is system major alarm module 1 inlet temperature: 25C
threshold #1 for module 1 inlet temperature:
(sensor value > 60) is system minor alarm
threshold #2 for module 1 inlet temperature:
(sensor value > 70) is system major alarm module 1 device-1 temperature: 30C
threshold #1 for module 1 device-1 temperature:
(sensor value > 60) is system minor alarm
threshold #2 for module 1 device-1 temperature:
(sensor value > 70) is system major alarm module 1 device-2 temperature: 29C
threshold #1 for module 1 device-2 temperature:
(sensor value > 60) is system minor alarm
threshold #2 for module 1 device-2 temperature:
(sensor value > 70) is system major alarm module 5 power-output-fail: OK
threshold #1 for module 5 power-output-fail:
(sensor value != 0) is system major alarm module 5 outlet temperature: 26C
threshold #1 for module 5 outlet temperature:
(sensor value > 60) is system minor alarm
threshold #2 for module 5 outlet temperature:
(sensor value > 75) is system major alarm module 5 inlet temperature: 23C
threshold #1 for module 5 inlet temperature:
(sensor value > 50) is system minor alarm
threshold #2 for module 5 inlet temperature:
(sensor value > 65) is system major alarm EARL 1 outlet temperature: N/O
threshold #1 for EARL 1 outlet temperature:
(sensor value > 60) is system minor alarm
threshold #2 for EARL 1 outlet temperature:
(sensor value > 75) is system major alarm EARL 1 inlet temperature: N/O
threshold #1 for EARL 1 inlet temperature:
(sensor value > 50) is system minor alarm
threshold #2 for EARL 1 inlet temperature:
(sensor value > 65) is system major alarm