• Run=50~2000 msec. (LINE move time adjustment)
Bit Rate – Display ON/OFF
Displays the bit rate of MP3 files.
Version – CON:XX (Control version)
Displays the firmware version.
• DSP:XX (DSP version)
• SER:XX (Servo version)
Load Default – Press TRACK Knob to enter load defaults. (LCD displays "Load OK".)
Will reset all settings to factory default except for Firmware version.
Exit & Save – Exit & Save setting to next power on (LCD displays "Saving".)
This will save all changes if changes are not saved the unit will revert to last saved changes on power off.
Press the TRACK knob to fast exit & save in any operating mode.