Table C-1
Numeric Codes and Text Messages (continued)
Control panel message
163-Time & Date Not Set
164-MemorySize Error
164-MemorySize Error
201-Memory Error
213-Incompatible Memory Module in
Memory Socket(s) X, X, ...
214-DIMM Configuration Warning
219-ECC Memory Module Detected ECC
Modules not supported on this Platform
301-Keyboard Error
ENWW
Description
RTC (real-time clock) battery may need to
be replaced.
CMOS jumper may not be properly installed. Check for proper placement of the CMOS
Memory amount has changed since the last
boot (memory added or removed).
Memory configuration incorrect.
RAM failure.
A memory module in memory socket identified
in the error message is missing critical SPD
information, or is incompatible with the
chipset.
Populated DIMM Configuration is not
optimized.
Recently added memory module(s) support
ECC memory error correction.
Keyboard failure.
Recommended action
See the Hardware Reference Guide on the
Documentation and Diagnostics CD for
instructions on installing a new battery, or
contact an authorized dealer or reseller for
RTC battery replacement.
jumper if applicable.
Press the
F1
key to save the memory changes.
Run Computer Setup or Windows
1.
utilities.
Make sure the memory module(s) are
2.
installed properly.
If third-party memory has been added,
3.
test using HP-only memory.
Verify proper memory module type.
4.
Run Computer Setup or Windows
1.
utilities.
Ensure memory modules are correctly
2.
installed.
Verify proper memory module type.
3.
Remove and replace the identified faulty
4.
memory module(s).
If the error persists after replacing
5.
memory modules, replace the system
board.
Verify proper memory module type.
1.
Try another memory socket.
2.
Replace DIMM with a module
3.
conforming to the SPD standard.
Rearrange the DIMMs so that each channel
has the same amount of memory.
If additional memory was recently
1.
added, remove it to see if the problem
remains.
Check product documentation for
2.
memory support information.
Reconnect keyboard with workstation
1.
turned off.
Check connector for bent or missing pins.
2.
Ensure that none of the keys are
3.
depressed.
Replace keyboard.
4.
POST numeric codes and text messages 109