Press the [ID.SET] button. The master panel whose ID is already assigned will not respond but the 2
without an ID # will activate to have ID.02. The same method is used to assign ID numbers to all the
remaining panels. Do not use the same ID number to the different panels, since individual adjustment
cannot be done.
There is no need to disconnect all the RJ45 control links to assign ID, the ID # can be set
one by one in the Link connection order.
In case of the new wireless remote control, operation is different from above method, use buttons as:
[ADJUST] [ID] [NUMBER] "0" appears [ENTER] [UP] "1" appears [ENTER] [ID SET]
Bring the wireless remote to the place at the IR sensor for each set and do the same to assign. Using RS232C
Link will enter little more difficulty, assigning in front of each panel will end up much efficient ID numbering.
To escape from this ID mode, select 'Input ID number' page and use [ADJUST] button.
When a panel ID is already set, you can change it by using the same procedure. Go to ID mode, open
'Input ID number' page, and then press the [ID.CLR] button. The OSD will indicate _ _ at the ID number
area. Now the new ID can be set after the old ID was erased.
Each panel should have one ID number assigned. Avoid using the same # on different panels as this will
make it difficult to perform certain adjustments.
Once ID number is set, it will remain (even after factory reset or firmware rewrite) until ID be re-assigned.
Clearing I.D.
Press [ADJUST] to enter Adjust Mode and then press [ID.ALL] to enter ID Mode, in the Input ID Number
Page, then press [ID.CLR] to erase the current I.D. number.
By wireless remote, [ADJUST] [ID] [ID CLR].
Setting I.D.
Press [ID.ALL] so that 'INPUT ID NUMBER' appears and enter the desired 2 digits I.D. using the
alpha-numeric keys. Press [ID.SET] to assign the I.D. – the OSD will disappear and the unit will return to
Normal Mode.
[ADJUST] [ID] [NUMBER] "0" [UP] # [ENTER] [UP] # [ENTER] [ID SET]
Selecting I.D.
If using Cube Commander software simply select the two digits I.D. for the cube you wish to control.
If [ID.ALL] is pressed instead of an alpha-numeric key '
**
display '
' (two wild cards) which will allow to control of all units simultaneously.
Wireless remote will not create RS232C code so that RJ-45 link will not work to send commands to the
other panel, ID numbering and special adjustments such as Lamp ballast power, picture effect memory
and others are possible but not for use of all the panel ** adjustments, use PC and RS232C for such.

*** Adjust Mode

Some adjustments have already been explained in previous pages. Below are more adjustments performed
in Adjust Mode.
White Balance adjustment
There are five independent memories for white balance selection. Press WB in NORMAL mode
to select the desired memory (WB1 - 5) before making adjustments. It is recommended to use USER
position to make adjustments since others are pre-set to each color temperature.
By wireless remote:
*
' will appear, pressing [ID.ALL] twice will
29
RS232C CONTROL
panel
nd
RS232C CONTROL