[ADJ.G] or [ADJ.B] button for other color selection. No other buttons be functional except other adjustment
modes. This means, from Contrast adjustment mode, we can enter to brightness or others but not for inputs.
The clock and phase are only for RGB input. Color, Tint and Sharpness are for video input only adjustments.
Saving adjustments
Adjusted value is saved in non-volatile memory when [WRITE] button is clicked. If the newly adjusted value
is not acceptable, simply shutting off the power by the rocker switch will erase it and go back to "before
adjustment" value. After [WRITE] button is used, the monitor would back to Normal Mode.
Adjustment parameters
All parameters except 'Magnification' and 'Position' can be adjusted using the right side buttons as:

Setting ID

When panels are installed, before doing adjustments, it is necessary to assign an ID number since the new
sets do not have any ID number already assigned. The ID number area is 2 digits. 00 to 99 and AA to FF
are possible to use. Mixing these numbers such as A0, A1 --- A9, AA will indicate A-10 and AF will be A-16.
The same extension applies for B1, B2 – BF up to FF, totaling 256 sets with an assigned ID.
Before assigning ID, it is necessary to wire RS232C cable from PC (Video Wall Controller software installed)
and RJ45 link.
With the new wireless remote control, it is also possible to assign ID number.
ID number, we need to enter [ADJUST] mode at first with ** selection of ID area by software. Then, click
[ID ALL] button to enter ID mode, OSD becomes as shown in below left. This is the page to type ID number.
In case of the new Remote Control, simply press [ADJUST] then [ID].
If typed wrong, just over-write the number until the right number is obtained.
Any number selected from 0 to F will work fine. This example is typed as 01 for ID #.
Pressing the [ID.SET] button will add own ID number to the 1
other ID numbers for the remaining panels need to be assigned. Enter ID mode again by pressing [ADJUST],
[ID.ALL] buttons to have the input ID number page appear again. Now type in a different number from
master panel, such as 02, this is displayed on the 1
buttons.
The 'Position' or 'Magnification' are adjusted using the left side
buttons by software, by remote control, use
(master) panel. After this operation, all the
st
and 2
panels.
st
nd
28
RS232C control
When [OFFSET] or [GAIN]
Button is clicked in adjust mode
the 1
entry will indicate the
st
"red" adjustment or default
adjustment. In this case, we
use the push [up] / [down]
buttons located on the right
side of the wired remote control
to do an adjustment, then press
To assign an
With this left example,
own ID = not assigned
Typed ID = 01
After typing 01 (ID), then
[ID.SET] is to be used to
set own ID.
.