Field
Summary Group
Switch Type
First Port Address
World Wide Name
Serial Number
Reason for Status
Vendor
MAC Address
Negotiated Domain ID
Configured Domain ID
Domain ID Lock
Number of Ports
Operational State
Administrative State
Configured Admin State
Beacon Status
Status Group
Operational State
Administrative State
Configured Admin State
Beacon Status
Reason for Status
Temperature
Power Supply 1 Status
Temperature Failure Port
Shutdown
Warning Temperature
Failure Temperature
POST Status
POST Fault Code
Test Status
50
Table
8.
Description
Switch model
Switch Fibre Channel address
Switch world wide name
Number assigned to each chassis.
The reason for the operational state.
Switch manufacturer
Media Access Control address
The domain ID currently being used by the fabric
The domain ID, defined by network administrator
Domain ID lock status. Prevents (True) or permits (False) dynamic
domain ID reassignment.
Number of physical ports on the switch
Switch operational state: Online, Offline, Diagnostic, Down
Current switch administrative state
Administrative state that is stored in the switch configuration
Beacon status. Switch LEDs are blinking (On) or not blinking (Off).
Switch operational state: Online, Offline, Diagnostic, Down
Current switch administrative state
Administrative state that is stored in the switch configuration
Beacon status. Switch LEDs are blinking (On) or not blinking (Off).
The reason for the operational state.
Internal switch temperature °C
Power Supply 1 Status
Non-configurable (always enabled for this switch). All ports are shut
down when the switch temperature exceeds the Failure Temperature.
Non-configurable temperature threshold, above which a warning
condition alarm is generated.
Non-configurable temperature threshold, above which a failure
condition alarm is generated.
The current diagnostic state of the switch.
The code value for the last recorded diagnostic test result recorded on
the switch.
The current diagnostic test status of switch.