The Switch data window fields are described in
Table 8

Switch data window fields

Field
Summary Group
Switch Type
First Port Address
World Wide Name
Serial Number
Reason for Status
Vendor
MAC Address
Negotiated Domain ID
Configured Domain ID
Domain ID Lock
Number of Ports
Operational State
Administrative State
Configured Admin State
Beacon Status
Status Group
Operational State
Administrative State
Configured Admin State
Beacon Status
Reason for Status
Temperature
Fan 1 Status
Fan 2 Status
Power Supply 1 Status
Power Supply 2 Status
Temperature Failure Port
Shutdown
Warning Temperature
Failure Temperature
48
Table
8.
Description
Switch model
Switch Fibre Channel address
Switch world wide name
Number assigned to each chassis.
The reason for the operational state.
Switch manufacturer
Media Access Control address
The domain ID currently being used by the fabric
The domain ID, defined by network administrator
Domain ID lock status. Prevents (True) or permits (False)
dynamic domain ID reassignment.
Number of physical ports on the switch
Switch operational state: Online, Offline, Diagnostic, Down
Current switch administrative state
Administrative state that is stored in the switch configuration
Beacon status. Switch LEDs are blinking (On) or not blinking
(Off).
Switch operational state: Online, Offline, Diagnostic, Down
Current switch administrative state
Administrative state that is stored in the switch configuration
Beacon status. Switch LEDs are blinking (On) or not blinking
(Off).
The reason for the operational state.
Internal switch temperature °C
Fan 1 status (dual-power supply model only)
Fan 2 status (dual-power supply model only)
Power supply 1 status
Power supply 2 status (dual-power supply model only)
Non-configurable (always enabled for this switch). All ports
are shut down when the switch temperature exceeds the
Failure Temperature.
Non-configurable temperature threshold, above which a
warning condition alarm is generated.
Non-configurable temperature threshold, above which a
failure condition alarm is generated.