Fruclass in fru table and fruhistoryclass in fruhistorytable of HA MIB
shows other(1) for CP slot instead of cp(4) for DC SAN Director and
DC04 SAN Director.
CPstatus change trap is not generated on issuing HA failover for 4/256
SAN Director, but the failover happens and the CP status change oid
returns changed values.
Fabric OS CLI doesn't allow Port fencing policy addition for F_Port
when there are no F_ports on the switch.
Not getting GbE ports while performing EnumerateAssociatedInstances
on Brocade_LogicalSwitch.
Switch doesn't commit after firmwareDownload fail as 0x23 (time
out).
Appropriate message is not shown in the message box, when the
"Details" button in the "Service" tab of "HA" window is clicked.
High Availability: The error message thrown is not relevant or mean-
ingful, when the values for E_D_TOV and R_D_TOV in the "Configure"
tab of "Switch admin", are changed.
Incorrect output from agshow command.
Detected termination of zoned observed running repeated multiple
zone updates for several hours in different FIDs.
FICON FCIP Acceleration error - FCCU LinkBusy from non-Busy CU in
ReadStates.
Found 2 LUNs got disabled with "Rekey done with failure" after
overnight manual_rekey finished. [CVLC-1001], 775/57, SLOT 2 |
FID 128, Nept_74, Manual re-key failed, LUN SN.
With Safezoning disabled, enabling defaultzoning via WT post con-
cerning messages that Safezoning was disable and defaultzoning was
enabled.
If second FDISC comes in before the switch responds to the first FDISC
between the same pair of devices, the Access Gateway daemon
panics.
In WebTools, for Add operation in VLAN in CEE tab, all created data
is not added in the table.
FCAP works only in Non-VF mode or VF mode with Default Switch.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change: A.
DCFM can be used to add the port
fencing policy for F_Port. B. Existing
Fabric OS CLI can always be used to
add port fencing policy after bringing
up F_Port on a switch. Adding port
fencing policy for F_Port makes sense
only when there are F ports on a
switch and anyway the existing CLI
behavior takes care of this.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Re-enable LUN.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0