Before committing configurations or modifications to the CTC or LUNs on an HP Encryption Switch
or HP Encryption Blade, make sure that there are no outstanding zoning transactions in the switch
or fabric. Failure to do so results in the commit operation for the CTC or LUNs failing and may
cause the LUNs to be disabled. The user can check for outstanding zoning transactions by issuing
the CLI command cfgtransshow:
DCX_two:root> cfgtransshow
There is no outstanding zoning transaction
Each LUN is uniquely identified by the HP Encryption Switch or HP Encryption Blade using the
LUN's serial number. The LUN serial numbers must be unique for LUNs exposed from the same
target port. The LUN serial numbers must also be unique for LUNs belonging to different target
ports in nonmultipathing configurations. Failure to ensure unique LUN serial numbers results in
nondeterministic behavior and may result in faulting of the HP Encryption Switch or HP Encryption
Blade.
When creating an HA cluster or EG with two or more HP Encryption Switch/Encryption Blades,
the GE ports (I/O sync links) must be configured with an IP address for the eth0 and eth1 Ethernet
interfaces using ipaddrset. In addition, the eth0 and eth1 Ethernet ports should be connected
to the network for redundancy. These I/O sync links connections must be established before any
Re-Key, First Time Encryption, or enabling EE for crypto operations. Failure to do so results in HA
Cluster creation failure. If the IP address for these ports is configured after the EE was enabled for
encryption, HP Encryption Switch needs to be rebooted and Encryption Blades should be slot-
poweroff/slotpoweron to sync up the IP address information to the EEs. If only one Ethernet
port is configured and connected to a network, data loss or suspension of Re-Key may occur when
the network connection toggles or fails.
initEE will remove the existing master key or link key. Backup the master key by running
exportmasterkey and cryptocfg
cryptocfg
initEE. After initEE, regEE and enableEE, run cryptocfg
cover the master key previously backed up, or in the case of fresh install run cryptocfg
genmasterkey to generate a new master key. If you are using SKM, establish a trusted link with
SKM again. Certificate exchange between key vaults and switches are not required in this case.
The disable EE interface CLI cryptocfg --disableEE [slot no] should be used only to
disable encryption and security capabilities of the EE from the Fabric OS Security Admin in the
event of a security compromise. When disabling the encryption capabilities of the EE using the
noted commands, the EE should not be hosting any CTCs. Ensure that all CTCs hosted on the HP
Encryption Switch or HP Encryption Blade are either removed or moved to a different EE in the
HA Cluster or EG before disabling the encryption and security capabilities.
Whenever initNode is performed, new certificates for CP and KAC (SKM) are generated. Hence,
each time InitNode is performed, the new KAC Certificate must be loaded onto key vaults for
(SKM. Without this step, errors will occur, such as key vault not responding and ultimately key
archival and retrieval problems.
The HTTP server should be listening to port 9443. SKM is supported only when configured to port
9443.
When all nodes in an EG (HA Cluster or DEK Cluster) are powered down (due to catastrophic
disaster or a power outage to the data center) and later nodes come back online (in the event of
the Group Leader (GL) node failing to come back up or the GL node being kept powered down)
the member nodes lose information and knowledge about the EG. This leads to no crypto operations
or commands (except node initialization) being available on the member nodes after the power-
cycle. This condition persists until the GL node is back online.
Workaround. In the case of a data center power down, bring the GL node online first, before
bringing the other member nodes online.