Out of Memory due to switch not timing out in.telnetd processes.
Transmitted Rate / Received rates based on the Bytes Transmitted /
Bytes Received are greater than the peak rates (RateTxPeakByte &
RateRxPeakByte).
CP panic with FICUd crash occurred during supportsave operation.
Name Server daemon (nsd) panic occurs after enabling frame redirec-
tion.
RTWR error when going to translate domain.
400 Multiprotocol Router VE port doesn't recover after WAN issues.
In a large fabric (50+ switches), simultaneously disabling and enabling
all switches could result in some switches stuck in F2 (unconfirmed)
state.
In some rare scenarios, when HA Failover performed prior to Name
Server being in sync, RSCNs were delivered.
Test tool reports data miscompare during an overnight run.
Need for synchronization between DCBX FCoE priorities with that of
PFCs enabled.
FrustatusChanged trap and fruhistorytrap are not received when a slot
is removed or inserted.
Encrypted LUN gets into internal Encryption Engine (EE) LUN State:
Disabled (key not in sync) as a result of rekeying and HAC/DEK cluster
failover and failback.
As a result of I/O and crypto operations, three LUNs are in "Key ID
Unvailable" state and one LUN indicates that inquiry failed.
DMM used license can be reset after netinstall of Fabric OS.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Reboot the switch.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
This can be avoided by doing one of
the following after enabling
FMSMODE for the first time: -
switchdisable/switchenable
- hafailover - hareboot -
reboot.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Delay executing a cfgenable after
a cfgsave when there is frame RD
zone.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Disable and enable the switches that
are stuck in F2 (domain ID not yet
confirmed) state independently.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Reboot the Encryption Engine (EE).
Fixed in Fabric OS 6.3.0