Need to support a command "clear logging" to clear all debug log
messages accumulated.
CLI output consistency and input validation issues around key lifespan
option of a LUN.
High Availability : User is able to change the "desired distance" for
long distance "L0". User should not be able to change the "Desired
distance" if the "Long distance" value is "L0". It should always be
"N/A" for L0.
After firmware upgrade, FC FastWrite traffic sometimes fails.
A few VERIFYs are dumped out on DC SAN Director and Multiprotocol
Router Blade EX port stuck without showing switch name of the edge
fabric switch etc during edge switch firmwareupgrade.
FMS mode should be blocked when a logical switch is in 10 bit ad-
dressing.
TI Zone activation failed when pushing from DCFM to fabric with 6.2.0
and 6.1.2.
The drive is taken offline after container is failed back.
If configdownload is performed via DCFM, switch authentication
failure may occur.
Add FIP version 0 handling.
Address configdownload problems.
Due to race condition, daemons may panic during FID deletion and
creating without significant time delay in between.
Cold-failover within Port group for F_Port did not happen on Access
Gateway (AG).
Supportsave may show parity errors on disabled ports.
Switch Admin: Merge status dialog should display the status and
timestamp of last merge for FCoE Login.
Switch panic in kernel while access an iu that has already timed out
and freed.
Hosts on 4 Gb SAN switch for HP c-Class BladeSystem in Access
Gateway-mode lost their targets when failover happened from 1 trunk
group (with primary ports) to another trunk group (with shared area
ports) on 8 Gb 48 port blade of DC SAN Director.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Go to FOS mode and issue an
errclear command.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Input validation issues. Requires the
user to provide valid input.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Issue hafailover or hareboot.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0