FICON emulation failing.
Pending Merge:VTs/VIs disappear when rebooting the HP Storage-
Works Encryption SAN Switch that has all the physical connections
to targets and initiators.
As a result of creating a cryptoLUN, a host can use a target even
though they are not in the same zone.
FICUD panic and reboot on DCX occurs after executing a host com-
mand to display the switch.
Applications that write to a LUN that is being rekeyed may see I/O
errors.
Rekey of LUNs hosted through active/passive ports do not complete
if started on the passive path.
With McDATA default zone enabled, when numerous NPIV devices
in the default zone come online at the same time, some devices were
missing from the portcam table.
Fabric mode TT does not show all the flows when device port is dis-
abled and enabled back after TT monitor installation.
If using WebTools to perform cfgsaveactivetodefined with a zone file
close to the maximum size in an interop mode fabric with more than
20 switches, the weblinker process may get terminated.
In a mixed fabric of VF enabled and non-VF switches, a VF enabled
switch may not be able to detect the FID conflict with the other VF en-
abled switch, if there are non-VF switches in the path interconnecting
the VF enabled switches.
IPC message from module CALD to Management Server is dropped
by Management server. This causes CALD module to wait indefinitely.
44
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change: If
a Host and Target are no longer
zoned together, the user should also
remove the associated container (the
frame redirect zone) for this
Host/Target pair. This prevents
Host/Target communication for this
pair via the container (that is,
redirection).
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
When performing a rekeying
operation on the LUN, HP
recommends that you quiesce access
to that LUN.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
This is due to multiple devices logging
in simultaneously. So apply
portdisable to all ports connected
to the devices and apply
portenable sequentially. This will
resolve the issue. NPIV devices in
Interopmode 2 default zone is not
supported. NPIV devices should be
part of the active zone configuration.
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Follow the raslog errors FABR-1044
or FABR-1043 displayed by switches
in the fabric to identify the offending
switch and resolve the FID conflict.
Fixed in Fabric OS 6.3.0