Wiring a Door Sensing Device

The units can monitor the position of up to four doors/gates and may react to a change in their status with one of
the relays (not set as a control relay). For example, if a door is pried open or is held open after its relay deactivates,
the unit will record the breach in its transactions and can perform the following actions:
• Energize a relay to activate an alarm device such as a siren, light or CCTV camera.
• Main use is to terminate strike time early.
EXIT
REQ 4
COM
DOOR
STAT 4
EXIT
REQ 3
COM
DOOR
STAT 3
EXIT
REQ 2
COM
DOOR
STAT 4
EXIT
REQ 1
COM
DOOR
STAT 1
NOTE: Door sensing device should provide contact closure when door is closed.

Wiring the AutoCall Feature

Using the AutoCall feature, the unit will automatically call the main residence phone when a driveway sensor is
activated (any device that provides a contact closure). For example, when a visitor drives over a loop sensor that
is connected to the AutoCall feature, the unit will call the main residence phone automatically so the visitor can
speak to the resident without pressing the call button on the unit.
J6
J3
POSTAL
AUTO
J2
J5
J1
POWER
12VAC/DC
J4
IO Input Board
Input Board
(See page 6)
J7
J6
POSTAL
J3
AUTO
J2
J5
J1
POWER
12VAC/DC
J4
IO Input Board
Input Board
(See page 6)
In
Common
Loop
Use
Detector
18-24 AWG
Page 17
Common
Door Status
Use 18-24 AWG
NOTE: Additional sensing devices can be
connected to any of the 4 Door Stat inputs.