Basic Wiring Diagram - Chamberlain Icon26 series Owner's Manual

Elite series telephone entry system
Table of Contents

Advertisement

AUX
AUX
OUTPUT RELAYS
INPUT
POWER IN
(+)
(+)
(-)
(-)
GND
GND
RS-485 (3)
RS-485 (1)
(+)
(+)
(-)
(-)
GND
GND
RS-485 (4)
RS-485 (2)
/
POSTAL
EXIT
SWITCH
INPUT
It is MANDATORY that this unit is properly
Entry 1
Vehicular Gate
Master Gate Operator
(Strike Open Input)
Access Door
Solenoid
Dial
Connect two wires to the main vehicular gate operator or
door. The gate relay will be activated by either pressing 9 on
the resident's phone, entering a utility or resident keycode,
Gate 7-day timer or ElitePro remote programming software.

BASIC WIRING DIAGRAM

12V
AC/DC
VIDEO
OUT
TEL LINE IN
GATE
DOOR
RELAY
RELAY
CHASSIS
GROUND
CAMERA
VCR
RELAY
Gate Relay Terminal Connection
Normally Open
OR
TIP
RING
Telephone Line:
MUST be a dedicated line for the
Telephone Entry System unit
ONLY! NOTE: Installation where
fiber optic phone lines are present
may require additional
modifications from your telephone
provider. Contact your provider
for more information.
Use 18 AWG wire where possible 24 AWG
Removable Screw Terminal Connectors for Easy Wiring.
Entry 2
Door Relay Terminal Connection
Normally Closed
Maglock
Connect two wires to the secondary gate or door. The door
relay will be activated by either pressing 5 on the resident's
phone, Door 7-day timer or ElitePro remote programming
software.
Icon Page
15
Transformer
12 Vac (50VA)
(Provided)
Polarity does not matter
12 Vac
16.5 Vac
(50 VA)
(50 VA)
Maximum
Maximum
Wire
Distance
Distance
Gauge
(Provided)
(Optional)
30 Ft
50 Ft
22 AWG
45 Ft
85 Ft
20 AWG
75 Ft
135 Ft
125 Ft
220 Ft
18 AWG
185 Ft
345 Ft
16 AWG
Pedestrian Gate
OR
Entry Door
Maglock
Dial

Advertisement