Removing And Replacing Field Replaceable Units; Removing A Microprocessor And Heat Sink - IBM HS12 - BladeCenter - 8028 Service Manual

Problem determination and service guide
Hide thumbs Also See for HS12 - BladeCenter - 8028:
Table of Contents

Advertisement

11. Turn on the blade server, start the Configuration/Setup Utility program, and

Removing and replacing field replaceable units

Use this information to remove and replace field replaceable units (FRUs).
FRUs must be installed only by trained service technicians. The illustrations in this
document might differ slightly from your hardware.

Removing a microprocessor and heat sink

Use this information to remove a microprocessor and heat sink from the blade
server.
Read the following important guidelines before you remove a microprocessor that
is not faulty (for example, when you are replacing the system-board assembly).
If you are not replacing a defective heat sink or microprocessor, the thermal
material on the heat sink and microprocessor will remain effective if you carefully
handle the heat sink and microprocessor when you remove or install these
components. Do not touch the thermal material or otherwise allow it to become
contaminated.
Notes:
1. The microprocessor and heat sink assembly is a field-replaceable unit (FRU)
2. The heat-sink FRU is packaged with the thermal material applied to the
3. A heat-sink FRU can be ordered separately if the thermal material becomes
To remove a microprocessor, complete the following steps.
60
BladeCenter HS12 Type 8014, 8028 or 1916: Problem Determination and Service Guide
reset the configuration (see "Setup and configuration overview" on page 19
for instructions).
and must be replaced by a trained service technician. To contact an IBM service
representative, see "Hardware service and support" on page 177.
underside. This thermal material is not available as a separate FRU. You must
replace the heat sink when new thermal material is required, such as when a
defective microprocessor is replaced or if the thermal material is contaminated
or has come in contact with another object other than its paired microprocessor.
contaminated.