v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing, Types 8014, 8028 and 1916," on page 25 to determine which components are CRUs
and which components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
00151000
SERR: Signaled Target Abort Slot=xx Vendor
ID=xxxx Device ID=xxxx Status=xxxx
00151100
MCA: Recoverable Error Detected Proc
00151200
MCA: Unrecoverable Error Detected Proc
108
BladeCenter HS12 Type 8014, 8028 or 1916: Problem Determination and Service Guide
Action
1. If an optional expansion unit is installed, reseat it
- See "Removing an optional expansion unit" on
page 37 and "Installing an optional expansion
unit" on page 38.
2. Reseat the I/O expansion card in slot xx; then,
restart the blade server.
3. Replace the following components, one at a time,
in the order shown, restarting the blade server
each time:
a. I/O expansion card in slot xx -
b. Optional expansion unit (if one is installed) -
See "Removing an optional expansion unit"
on page 37 and "Installing an optional
expansion unit" on page 38.
c. (Trained service technician only) System-board
assembly - See "Removing the system-board
assembly" on page 65 and "Installing the
system-board assembly" on page 66.
1. Reseat the microprocessor.
2. Replace the following components, one at a time,
in the order shown, restarting the blade server
each time:
a. (Trained service technician only)
Microprocessor - See "Removing a
microprocessor and heat sink" on page 60 and
"Installing a microprocessor and heat sink" on
page 62.
b. (Trained service technician only)
System-board assembly - See "Removing the
system-board assembly" on page 65 and
"Installing the system-board assembly" on
page 66.
1. (Trained service technician only) Reseat the
microprocessor.
2. Replace the following components, one at a time,
in the order shown, restarting the blade server
each time:
a. (Trained service technician only)
Microprocessor - See "Removing a
microprocessor and heat sink" on page 60 and
"Installing a microprocessor and heat sink" on
page 62.
b. (Trained service technician only)
System-board assembly - See "Removing the
system-board assembly" on page 65 and
"Installing the system-board assembly" on
page 66.

Advertisement