Monitor Lamp indicators
TEMP indicator
J
Lamp
indication
Warm-up status
Lighting in red
High temperature
inside. (WARNING)
High temperature
Blinking in red
inside.
(once)
(Power ON condition)
High temperature
Blinking in red
inside.
(twice)
(Standby condition)
Blinking in red
Cooling fan has
(3 times)
been stopped.
Note
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
z
76
- ENGLISH
Information
Did you turn on the power when
z
the ambient temperature was
lower than approx. 0 °C (32 °F)?
Check the ventilation port is
z
blocked.
Is the room air temperature too
z
high?
Is the filter indicator lighted?
z
Check point
z
z
z
z
z
z
—
Remedial measure
Wait about 5 minutes in the current
status.
Install the unit in a location having
an ambient temperature from 0 °C
(32 °F) - 45 °C (113 °F).
Remove the object that is blocking
the ventilation port.
Move the projector to a temperature
of 0 °C (32 °F) - 45 °C (113 °F) and
the humidity of 20 % to 80 % (no
condensation).
Turn off the MAIN POWER switch
using the procedure on page 33 and
replace the ACF unit.
Turn off the MAIN POWER switch
using the procedure on page 33 and
consult the dealer.