31. Fill the rest of the groove with Loctite* 498 Adhesive. Verify under the microscope
that the thermocouple wire is below the surface along the entire length of the IHS
groove (Figure 7-33).

Figure 7-33. Filling Groove with Adhesive

32. To speed up the curing process apply Loctite* Accelerator on top of the Adhesive
and let it set for a couple of minutes (Figure 7-34).

Figure 7-34. Application of Accelerant

100
Case Temperature Reference Metrology
Thermal and Mechanical Design Guidelines