Monitor Problems - IBM 8647 - Eserver xSeries 225 Installation Manual

Installation guide
Hide thumbs Also See for 8647 - Eserver xSeries 225:
Table of Contents

Advertisement

Monitor problems

Monitor symptom
The screen is blank.
Only the cursor appears.
The screen is wavy, unreadable,
rolling, distorted, or has screen
jitter.
Wrong characters appear on the
screen.
No video.
58
IBM xSeries 225 Type 8647: Installation Guide
Suggested action
Verify that:
v The server power cord is plugged into the server and a working electrical outlet.
v The monitor cables are connected properly.
v The monitor is turned on and the Brightness and Contrast controls are adjusted
correctly.
v If the servers are C2T chained together, verify that:
– The C2T chain cables are securely connected to the servers.
– The C2T breakout cable is connected properly.
– A server that is turned on is selected.
Important: In some memory configurations, the 3-3-3 beep code might sound
during POST followed by a blank display screen. If this occurs and the Boot Fail
Count feature in the Start Options of the Configuration/Setup Utility program is set
to Enabled (its default setting), you must restart the server three times to force the
system BIOS code to reset the CMOS values to the default configuration (memory
connector or bank of connectors enabled).
If the problem remains, call for service.
Call for service.
If the monitor self-tests show the monitor is working properly, consider the location
of the monitor. Magnetic fields around other devices (such as transformers,
appliances, fluorescent lights, and other monitors) can cause screen jitter or wavy,
unreadable, rolling, or distorted screen images. If this happens, turn off the monitor.
(Moving a color monitor while it is turned on might cause screen discoloration.)
Then move the device and the monitor at least 305 mm (12 in.) apart. Turn on the
monitor.
Notes:
1. To prevent diskette drive read/write errors, be sure the distance between
monitors and diskette drives is at least 76 mm (3 in.).
2. Non-IBM monitor cables might cause unpredictable problems.
3. An enhanced monitor cable with additional shielding is available for the 9521
and 9527 monitors. For information about the enhanced monitor cable, contact
your IBM reseller or IBM marketing representative.
If the problem remains, call for service.
If the wrong language is displayed, update the BIOS code with the correct
language.
If the problem remains, call for service.
1. Make sure the correct machine is selected, if applicable.
2. Make sure all cables are locked down.
If the problem remains, call for service.

Advertisement