Resetting Ilo 2; Server Name Still Present After Erase Utility Is Executed; Troubleshooting A Remote Host - HP AB500A - Integrated Lights-Out Advanced User Manual

Hp integrated lights-out 2 user guide for firmware 1.75 and 1.77
Hide thumbs Also See for AB500A - Integrated Lights-Out Advanced:
Table of Contents

Advertisement

You can also use Microsoft® LDP tool to verify SSL connections. For more information on the LDP tool, go
to the Microsoft® website (http://www.microsoft.com/support).
An old certificate can cause problems with SSL can on the domain controller when it points to a
previously trusted CA with the same name, which is rare but might happen if a certificate service is added
and removed and then added again on the domain controller. To remove old certificates and issue a new
one follow the instructions in Step 2.

Resetting iLO 2

In rare instances, it might be necessary to reset iLO 2; for example, if iLO 2 is not responding to the
browser. To reset iLO 2, you must power down the server and disconnect the power supplies completely.
iLO 2 might reset itself in certain instances. For example, an internal iLO 2 watchdog timer resets if the
firmware detects an iLO 2 problem. If a firmware upgrade is completed or a network setting is changed,
iLO 2 also resets.
The HP Insight Management Agents 5.40 and later have the ability to reset iLO 2. To reset iLO 2, choose
one of the following options:
Select the Reset iLO 2 option on the HP Management Agent web page under the iLO 2 section.
Click Apply on the Network Settings page to manually force the iLO 2 management processor to
reset. You do not need to change any parameters before clicking Apply.
Click Reset on the Diagnostic page of the iLO 2 browser interface.

Server name still present after ERASE utility is executed

The Server Name field is communicated to iLO 2 through the Insight Manager Agents.
To remove the Server Name field after a redeployment of a server, do one of the following:
Load the Insight Manager Agents to update the Server Name field with the new server name.
Use the Reset to Factory Defaults feature of the iLO 2 RBSU utility to clear the Server Name field.
This procedure clears all iLO 2 configuration information, not just the Server Name information.
Change the server name on the Administration>Access>Options page on the iLO 2 browser
interface.

Troubleshooting a remote host

Troubleshooting a remote host server might require restarting the remote system. You can restart the
remote host server by using the options listed in the Virtual Devices tab.
Troubleshooting iLO 2 212