The Enable Static IP Bay Configuration Settings checkbox, available on the Network Settings tab (not
shown), allows you to enable or disable Static IP Bay Configuration. The new Enable Static IP Bay
Configuration Settings option is only available on blade servers. When Static IP Bay Configuration is
enabled, all fields except iLO 2 Subsystem Name are disabled. Only Static IP Bay Configuration or DHCP
can be enabled at one time. Disabling both Static IP Bay Configuration and DHCP signals iLO 2 to use a
user-defined IP address. The Enable Static IP Bay Configuration Settings option remains disabled if the
infrastructure does not support Static IP Bay Configuration.
ProLiant BL p-Class standard configuration parameters
Beginning IP Address (Bay 1)—Assigns the starting IP address. All IP addresses must be valid addresses.
Ending IP Address (Bay 16)—Assigns the ending IP address. All IP addresses must be valid addresses.
Subnet Mask—Assigns the subnet mask for the default gateway. This field may be filled in if either Static
IP Bay Configuration or DHCP is enabled. The entire IP address range must conform to the subnet mask.
Gateway IP Address—Assigns the IP address of the network router that connects the Remote Insight subnet
to another subnet where the management PC resides. This field may be filled in if either Static IP Bay
Configuration or DHCP is enabled.
ProLiant BL p-Class advanced configuration parameters
Domain Name—Enables you to assign the name of the domain in which the iLO 2 will participate.
Primary DNS Server—Assigns a unique DNS server IP address on your network.
Secondary DNS Server—Assigns a unique DNS server IP address on your network.
Tertiary DNS Server—Assigns a unique DNS server IP address on your network.
Primary WINS Server—Assigns a unique WINS server IP address on your network.
Secondary WINS Server—Assigns a unique WINS server IP address on your network.
Configuring iLO 2 71