For more information see to the HP Integrated Lights-Out Management Processor Scripting and Command
Line Resource Guide.
To configure alerts:
Log in to iLO 2 using an account that has the Configure iLO 2 Settings privilege.
1.
Select Management in the Administration tab. The SNMP/Insight Manager Settings screen appears.
2.
In the SNMP Alert Destination(s) fields, enter up to three IP addresses that you want to receive the
3.
SNMP alerts and select the alert options you want iLO 2 to support.
Click Apply Settings.
4.
Test alerts include an Insight Manager SNMP trap and are used to verify the network connectivity of iLO 2
in HP SIM. Only users with the Configure iLO 2 Settings privilege can send test alerts.
Be sure you have saved any changes to the SNMP Alert Destination(s) fields before sending a test alert.
To send a test alert:
Select Management in the Administration tab. The SNMP/Insight Manager Settings screen appears.
1.
Click Send Test Alert in the Configure and Test SNMP Alerts section to generate a test alert and send
2.
it to the TCP/IP addresses saved in the SNMP Alert Destinations fields.
After generating the alert, a confirmation screen appears.
3.
Check the HP SIM console for receipt of the trap.
4.

SNMP generated trap definitions

You can generate the following SNMP traps on BL c-Class servers and iLO 2:
ALERT_TEST is used to verify that the SNMP configuration, client SNMP console, and network are
operating correctly. You can use the iLO 2 interface to generate this alert to verify receipt of the alert
at the SNMP console. You can also generate this alert using the iLO 2 Option ROM to verify SNMP
configuration settings.
ALERT_SERVER_POWER occurs when the iLO 2 management processor detects an unexpected
transition of the host system power, either from ON to OFF, or OFF to ON. Transitions of the host
system power are unexpected when the change takes place because of events unknown to the
management processor. This alert is not generated when the system is powered up or down using
Configuring iLO 2 67