Dynamic Power Capping For Server Blades - HP AB500A - Integrated Lights-Out Advanced User Manual

Hp integrated lights-out 2 user guide for firmware 1.75 and 1.77
Hide thumbs Also See for AB500A - Integrated Lights-Out Advanced:
Table of Contents

Advertisement

Field
Subnet Mask
Gateway
Domain
DNS Server 1
DNS Server 2
DNS Server 3
NTP Server 1
NTP Server 2

Dynamic power capping for server blades

Dynamic power capping is an iLO 2 feature available for c-Class server blades and accessed through HP
Onboard Administrator. For more information on all the power setting options for c-Class server blades,
see the HP BladeSystem Onboard Administrator User Guide.
Dynamic power capping is only available if your system hardware platform, BIOS (ROM), and power
micro-controller firmware version support this feature. If your system is capable of performing dynamic
power capping, iLO 2 automatically functions in Dynamic Power capping mode.
In Onboard Administrator, there are two Dynamic Power capping options:
Dynamic Power
If enabled, Dynamic Power automatically places unused power supplies in standby mode to increase
enclosure power supply efficiency, thereby minimizing enclosure power consumption during lower
power demand. Increased power demands automatically return standby power supplies to full
performance. If Dynamic Power is:
Enabled (default setting)—Some power supplies can be automatically placed on standby to
o
increase overall enclosure power subsystem efficiency.
Disabled—All power supplies share the load. The power subsystem efficiency varies based on
o
load.
Enclosure Dynamic Power Cap
An optional setting that enables you to set a cap on a group of servers in an enclosure. Set the cap
between the values shown above the Enclosure Dynamic Power Cap field. These values are based
on the enclosure's current configuration.
Possible value
###.###.###.### where
### ranges from 0 to 255
###.###.###.### where
### ranges from 0 to 255
A character string, including
all alphanumeric characters
and the dash (-)
###.###.###.### where
### ranges from 0 to 255
###.###.###.### where
### ranges from 0 to 255
###.###.###.### where
### ranges from 0 to 255
###.###.###.### where
### ranges from 0 to 255
###.###.###.### where
### ranges from 0 to 255
Description
Subnet mask for the device or interconnect
bays
Gateway address for the device or
interconnect bays
The domain name for the device or
interconnect bays
The IP address for the primary DNS server
The IP address for the secondary DNS server
The IP address for the tertiary DNS server
The IP address of the primary server used to
synchronize time and date using the NTP
protocol
The IP address of the secondary server used to
synchronize time and date using the NTP
protocol
Using iLO 2 130

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xw460c - proliant - blade workstation

Table of Contents