Error Code/Symptom
01298001 (No update data for processor 1) 1. Ensure all processors are the same stepping level and cache size.
01298002 (No update data for processor 2) 1. Ensure all processors are the same stepping level and cache size.
01298101 (Bad update data for processor
1)
01298102 (Bad update data for processor
2)
I9990301 (Fixed boot sector error)
I9990305 (Fixed boot sector error, no
operating system installed)
I9990650 (AC power has been restored)
SCSI error codes
Error Code
All SCSI Errors One or more of the
following might be causing the problem:
v A failing SCSI device (adapter, drive,
controller)
v An improper SCSI configuration or SCSI
termination jumper setting
v Duplicate SCSI IDs in the same SCSI
chain
v A missing or improperly installed SCSI
terminator
v A defective SCSI terminator
v An improperly installed cable
v A defective cable
Temperature error messages
Message
DASD Over recommended Temperature
(sensor X) (level-warning; DASD bay "X"
had over temperature condition)
DASD under recommended temperature
(sensor X) (level-warning; direct access
storage device bay "X" had under
temperature condition)
FRU/Action
2. Processor 1
2. Processor 2
1. Ensure all processors are the same stepping level and cache size.
2. Processor 1
1. Ensure all processors are the same stepping level and cache size.
2. Processor 2
1. Hard Disk Drive
2. Cable
3. SCSI Backplane
4. System Board
1. Install operating system to hard disk drive.
1. Check power cable
2. Check for interruption of power supply
3. Power Cable
FRU/Action
1. External SCSI devices must be powered-on before you power-on
the server/workstation.
2. The cables for all external SCSI devices are connected correctly.
3. If you have attached an external SCSI device to the
server/workstation, make sure the external SCSI termination is set
to automatic.
4. The last device in each SCSI chain is terminated correctly.
5. The SCSI devices are configured correctly.
Action
1. Ensure system is being properly cooled; see "Temperature
checkout" on page 25.
1. Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 4.
131