IBM 867413x - Eserver xSeries 330 8674 Hardware Maintenance Manual page 132

Type 8674, intellistation r pro type 6851, and network equipment building system type 8674
Table of Contents

Advertisement

Error Code/Symptom
089-XXX-001 (Failed Microprocessor test)
089-XXX-002 (Failed Optional
Microprocessor test)
165-060-000 (Service Processor: ASM may
be busy)
165-198-000 (Service Processor: Aborted)
165-201-000 (Service Processor: Failed)
165-330-000 (Service Processor: Failed)
165-342-000 (Service Processor: Failed)
180-XXX-000 (Diagnostics LED failure)
180-XXX-001 (Failed information LED panel
test)
180-XXX-003 (Failed System Board LED
test)
180-XXX-005 (Failed SCSI Backplane LED
test)
201-XXX-0NN (Failed Memory test, see
"Memory Settings" on page 30)
201-XXX-999 (Multiple DIMM failure, see
error text)
202-XXX-001 (Failed System Cache test)
202-XXX-002 (Failed System Cache test)
124
Hardware Maintenance Manual: xSeries 330 Type 8674, IntelliStation R Pro Type 6851, and Network Equipment Building
System Type 8674
FRU/Action
1. Microprocessor 1
2. System Board
1. Microprocessor 2
2. System Board
1. Rerun the diagnostic test
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
4. System Board
1. Rerun the diagnostic test
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
4. System Board
1. Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
2. System Board. Before replacing the System Board, ensure that
System Board jumper J28 is not installed (the default) when the
error occurs.
1. Update to the latest ROM diagnostic level, and retry.
1. Ensure latest firmware levels for ASM and BIOS.
2. Disconnect all server/workstation and option power cords from
server/workstation, wait 30 seconds, reconnect, and retry.
3. System Board
1. Run Diagnostic LED test for the failing LED.
1. Switch Card / Information LED Panel
1. System Board
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
1. DIMM Location slots 1-4 where NN = DIMM location.
Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN
4=DIMM 4
2. System Board
1. See error text for failing DIMMs
2. System Board
1. Microprocessor 1
2. System Board
1. Microprocessor 2
2. System Board

Advertisement