Connecting The Power-Supply Adapter - IBM 867413x - Eserver xSeries 330 8674 Hardware Maintenance Manual

Type 8674, intellistation r pro type 6851, and network equipment building system type 8674
Table of Contents

Advertisement

10. Connect one end of the ASM link cable (Category 5 cable) to the ASM
11. Turn on the server.
Continue with "Connecting the power-supply adapter".

Connecting the power-supply adapter

You may attach the power-supply adapter that comes with the Remote Supervisor
Adapter. After you connect the power supply adapter to the Remote Supervisor
Adapter, you can use the power cord to connect the power supply adapter to a
properly grounded electrical outlet or use the universal power cord (comes with
the Remote Supervisor Adapter) to connect the power supply adapter to a power
distribution unit (PDU) or to an uninterruptible power supply (UPS).
Note: Alternatively, power can be supplied to the adapter by connecting the
To connect the power-supply adapter and power cord, complete the following
steps:
1. From the power-supply adapter 3 , connect the power-supply control cable
Attention: Route cables so that they do not block the flow of air from the
fans.
8. Replace the cover on the server; then, reinstall the server in the rack (if
applicable) and connect all external cables.
9. Connect the ASM Interconnect module to the Remote Supervisor Adapter
using the ASM Interconnect port (P-P port) that is located on the adapter.
Interconnect module, and the other end to the ASM Interconnect port that is
located on the back of your server.
system-management connector of the adapter to the Remote Supervisor
Adapter connector (J57) on the system board using the 20-pin ribbon cable
that comes with the adapter.
2 to the power-supply adapter connector on the Remote Supervisor Adapter
ASM link cable
ASM Interconnect
module
65