Environmental; Reliability; Safety And Emi Performance; Table 9. Environmental Characteristics - Planar EL240.128.45 ICEBrite User Manual

El small graphics display
Table of Contents

Advertisement

Environmental

Table 9. Environmental Characteristics.

Temperature
Operating
Operating survival
Non-operating
Humidity
Operating
Non-operating
Altitude
Operating/non-operating
Vibration
Operating/non-
operating
Mechanical Shock
Operating/non-
operating
Thermal Shock
Displays are non-operating during the tests performed per IEC 68-2-14. Test Na.

Reliability

The display MTBF is demonstrated to be greater than 100,000 hours at
maximum frame rate with a 90 % confidence level at 25 °C.

Safety and EMI Performance

The display will not inhibit the end product from complying with FCC Part
15 Subpart J, Class B and EN55022 Class B when housed in a suitable
enclosure.
The display will be a recognized component under UL1950 by
Underwriters Laboratories. The display will not inhibit the end product
from complying with CSA C22.2 No. 950 and EN60950.
-20 °C to +70 °C
-40 °C to +85 °C
-50 °C to +105 °C
to 93 % RH max @ 40 ºC, per IEC 68-2-3
(Non-condensing)
to 95 % RH max @ 25-55 °C, per IEC 68-2-30 (Condensing)
0 to 18,000 m per IEC 68-2-13
2
0.02 g
/Hz, 5-500 Hz, 30 minutes on
each axis, per IEC 68-2-36, Random
100 g, 6 ms duration (half sine wave), three shocks per
surface (6), tested per IEC 68-2-27, Test Ea
-40 °C for 30 min., room temperature for ~3 min., then
85 °C for 30 min. Cycle repeated five times.
EL240.128.45 Operations Manual (020-0345-00C)
After 12 hours at -50 °C, display
must be at -40 °C for 1 hour prior to
power on.
13