Environmental Specifications - Planar UltraRes 4K User Manual

4k professional displays
Hide thumbs Also See for UltraRes 4K:
Table of Contents

Advertisement

LCD Optical Specifications (Continued)
Viewing Angle
Color gamut
Number of colors
Native resolution

Environmental Specifications

Specification
Temperature
operating
non-operating
Altitude (barometric pressure)
Humidity
operating
non-operating
Low line voltage range
High line voltage range
Line frequency range
Acoustic Noise
Inrush current
Power consumption
Standby
Normal operation
86
Specification
2D content
3D content left/right
3D content up/down
Red (x,y)
Green (x,y)
Blue (x,y)
White (x,y)
Native color temperature
Maximum
40° C
104° F
60° C
140° F
3000m
85% R.H.
90% R.H.
550W
Planar UltraRes User Manual
Maximum
Minimum
Optimal
0° C
20-25° C
32° F
–20° C
20° C
–4° F
+/- 10° C
100-120V
200-240V
49-61Hz
60A
< 0.5W
465W typ.
Minimum
89° in all directions
89° in all directions
26° combined
30° combined
72% NTSC
100% REC709
0.645, 0.335
0.300, 0.620
0.150, 0.060
0.279, 0.292
10,000K
1 billion
3840 x 2160
Notes
All performance specifications are
maintained within this temperature range.
non-condensing
non-condensing
Fanless
550W x 3.42 BTU = 1881 BTU/hr max.
465W x 3.42 BTU = 1590 BTU/hr typ.
Typical

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultrares ur8450-lxUltrares ur8450-mxUltrares ur8450-3d

Table of Contents