Table 6. Environmental Characteristics.

Temperature
Survival
Humidity
Non-condensing
Condensing
Altitude
Tested per IEC 68-2-13
Vibration
Random
Operating/non-operating
Shock
Operating/non-operating
The display MTBF is demonstrated to be greater than 100,000 hours at 25°C
with a 90% confidence level.
The display will not inhibit the end product from obtaining these safety
certifications: IEC 601-1, UL544 or CSA 22.2 #601-M89.
The display will not inhibit the end product from complying with FCC Docket,
Part 15, Subpart J, Class B; CISPR 11, Class B; and VDE 871/VFG 243, Class B
when housed in a suitable enclosure.
Operating
-25°C to +65°C
-25°C to +75°C
to 93% RH max @ 40ºC, per IEC 68-2-3
-1000 to 16,000 ft
(-3048 to 48,768 m)
0.02g 2 /Hz, 20-500 Hz, 30 minutes on each axis, per IEC 68-2-36,
test Fdb.
100 g, 6 ms, half sine wave per IEC 68-2-27, test Ea.
Non-operating
-40°C to +75°C
to 95% RH max @ 55°C,
per IEC 68-2-30
-1000 to 58,000 ft
(-3048 to 176,784 m)