Step 6: Electrical Requirements - Thermador PRD484EEHU Installation Manual

Dual fuel ranges
Hide thumbs Also See for PRD484EEHU:
Table of Contents

Advertisement

Available languages

Available languages

I
,
!
'\
./
Figure 8: Location of Gas Supply Inlet Connection on 48" Ranges
Step 6: Electrical Requirements, Connection &
Grounding
Prior to servicing appliance, always disconnect appliance electrical supply cord,
if so equipped, from wall receptacle. If appliance is hard-wired to power supply,
disconnect power to unit by turning off the proper circuit breaker or disconnect-
ing the proper fuse. Lock service panel to prevent power from being turned ON
accidentally.
Dual Fuel range models can be connected or hardwired to the power supply as
described on Page 19.
iiiiii i_iiiiii_!H_iiiiii!ii!!I!iii
iiil!ii_ _iii!i! iii! _/iiiiiii_i_i_ii
¸ii'iiii!!_i_!i_liil iii!
i
35 Amps x 2
30"
240/208 VAC
(35 Amps each
36
_'
240/208 VAC
240/208 VAC
48
_'
line)
35 Amps x 2
(35 Amps each
line)
50 Amps x 2
(50 Amps each
line)
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
A neutral supply wire must be provided from the power source (breaker/fuse
panel) because critical range components, including the surface burner spark
reignition module, require 120 VAC to operate safely and properly. An improper
120/240 VAC power supply will cause malfunction, damage this appliance, and
possibly create a condition of shock hazard. If the correct power supply circuit is
not provided, it is the responsibility and obligation of the installer and user to
have proper power supply connected. This must be accomplished in accor-
Page17