4 UpperNut
\,_\_/
(_-
V Cupped Washe r
,_:_
kg)_T. _4
SupplyWire
_Flat
Washer
3-Wire Lead Connection
Figure 11: Conductor
Securement
3-CONDUCTOR
CORD - WHERE LOCAL CODES AND ORDINANCES
PER-
MIT GROUNDING THROUGH NEUTRAL, AND CONVERSION
OF SUPPLY
TO 4 WIRE IS IMPRACTICAL,
UNIT MAY BE CONNECTED TO THE POWER
SUPPLY WITH A 3-POLE, 3-CONDUCTOR
CORD KIT RATED 125/250
VOLTS, 50 AMPERES, AND MARKED FOR USE WITH RANGES. The cord
kit must be attached to the range junction box with a strain relief which will fit a
1" diameter hole. If not already equipped, the cord must have 1/4" faston
closed-loop lugs attached to the free ends of the individual conductors, prefer-
ably soldered in place.
Installer - show the owner the location of the circuit breaker or fuse. Mark it for easy
reference.
A 3- or 4-conductor supply may be connected to the terminal block.
1.
Remove upper nuts only from the terminal block studs. Do not remove nuts
which secure range internal
wiring leads.
2.
Secure the neutral, grounded wire of the supply circuit, to the center stud of the
terminal block with nut. (See Figure 12).
3.
Secure the L1 (black) and L2 (red) power leads to the outside terminal block
studs (brass colored) with nuts.
4.
Tighten nuts securely.
L1 Black _t
,j
Neutral
White
,A
L2 Red
4-Wire Connection
Figure 12:3
Wire Connection
1.
Remove upper nuts only from the terminal block studs. Do not remove lower
nuts which secure range internal wiring
leads.
2.
Remove ground strap screw and bend the strap up as shown in Figure 13.
3.
Secure the neutral wire to the center stud of the terminal block with nut.
Page 20