Communications and File Transfers

Receiving Files Directly From A System Device (Serial Connections Only)

To receive files directly from a system device (Serial connections only):
1. In the Receive tab, click to select a file in the Files to Receive queue.
2. Click Edit to open the Edit menu and select Device Mapping. This opens the Enter DPS
dialog.
3. Enter the Device:Port:System (D:P:S) information for the selected file.
4. Check the Connect directly to the device - No Master... option.
5. Click OK.

Virtual NetLinx Master (Masterless) Transfers

NetLinx Studio v2.1 (or higher) supports direct connection to G4 panels via TCP/IP and USB, for
situations where the target panel is not connected to a NetLinx Master. In this situation, you can use
your PC's Ethernet or USB connectors to connect directly to the panel, using your PC as a Virtual
NetLinx Master.

Virtual Netlinx Master USB Transfers

TPDesign4 v2.2 (or higher) supports direct connection to G4 panels via USB (and TCP/IP), for
situations where the target panel is not connected to a NetLinx Master. In this situation, you can use
your PC's USB connection to connect directly to the panel, using your PC as a Virtual NetLinx
Master.
There are three basic steps to Virtual NetLinx Master USB file transfers:
If it is not already powered up and connected, apply power to the G4 panel and verify that it is
connected to the PC running NetLinx Studio via the USB connector on the rear (or side) of the
panel.
160
Virtual NetLinx Master supports both TCP/IP and USB connections.
Virtual NetLinx Master can be used to transfer TPDesign4 panel (.TP4) file, NetLinx
Firmware (.KIT) files, or IR Files directly to G4 touch panels.
G4 touch panels that support USB connection include the MVP-8400, MVP-7500 and
NXD/T-CV7.
USB direct transfers require that you configure the Master Connection setting on the
panel itself to USB prior to attempting the transfer.
TCP/IP direct transfers require that you configure the Master Connection setting on the
panel itself to TCP/IP prior to attempting the transfer.
Configuring the Touch Panel for Virtual NetLinx Master USB Transfers
Configuring NetLinx Studio for Virtual NetLinx Master USB Transfers
Transferring Files Using a Virtual NetLinx Master USB Connection