3. By default, the selected device is displayed in the Device to Bind/Unbind window at the top of
the dialog. If there is more than one Unbound device in the system, click the down arrow to
select which device you want to bind.
4. Check the checkbox next to the Master that you want to bind the device to. If there is more than
one Master in the system, check the specific Master that you want to bind the device to.
5. Select Refresh System (in the Device Tree context menu). The device should now appear in
the device list (indicated with a green device icon).
To Unbind a Bound Device:
1. Right-click on the device that you want to unbind in the Device Tree.
2. Select Unbind Device to open the Bind/Unbind Device dialog (FIG. 25).
3. De-select the checkbox next to the Master that the device is currently bound to.
4. Select Refresh System (in the Device Tree context menu). The device should now appear in
the Unbound Devices folder (indicated with a green device icon).

NetLinx Diagnostics - NetLinx Device Notification

The NetLinx Device Notifications functionality in NetLinx Studio v2 allows you to receive several
types of auto-notification messages from one or more specified NetLinx devices. Use the NetLinx
Device Notifications Options dialog (Diagnostics > NetLinx Device Notification Options) to set
auto-notification preferences for one or more NetLinx devices.

Adding A Device To The Device Notification List

In order to edit, add or remove devices from the list you must be connected to a NetLinx master
controller.
1. Select Diagnostics > NetLinx Device Notification Options to open the NetLinx Device
Notifications Options dialog.
2. Click Add to open the NetLinx Notification Properties (Add) dialog.
3. Specify the Device, Port and System numbers for the NetLinx device that you want to set
notification options for.
The D:P:S combination of 0:0:0 is the default setting and will show up as "All
Devices".
4. Check each notification type that you want to enable for that device.
NetLinx Studio (v2.4 or higher)
Select Enable NetLinx Device Notifications from the Diagnostics menu (or use the
toolbar button) to enable the specified NetLinx notifications. The resulting notification
messages are displayed in the Notifications tab of the Output Display window. The
Notifications tab contains 13 columns. Each column represents a notification type (which
are enabled/disabled in the NetLinx Notification Properties dialog). If a notification type
is enabled, the word ON is displayed in the appropriate column. Initially, the only entry
in the notifications list is All Devices, and the only notification enabled is Input.
Select the Enable Asynchronous Notifications option (in the NetLinx Device
Notifications Options dialog) to enable asynchronous notifications.