Figure 25. Device List Command Output
Adding an SATP Claim Rule to Enable ALUA and Change the Multipath Policy to Round Robin
To create the new claim rule, use the following command:
#esxcli storage nmp satp rule add -s VMW_SATP_ALUA -V DELL -M array_model -c
tpgs_on -P VMW_PSP_RR -e "Dell ALUA Claim Rule"
Valid values for
array_model
This command creates a new entry for the VMW_SATP_ALUA rule for any LUN matching the vendor ID (-V)
and model ID (-M) you specify. It also assigns the default path selection policy to round robin
(-P VMW_PSP_RR).
NOTE: There are different methods to manage SATP claim rules. Your environment may require different
parameters to enable ALUA support. Refer to the VMware Knowledge Base for additional information.
To verify that the new claim rule was created successfully, repeat the
command:
Figure 26.
Device List Command Output Following New Rule Creation
Networking Configuration for Fibre Channel and iSCSI Storage
(ESX/ESXi 4.x only)
The Dell MD3600i-series and MD3600f-series storage arrays are not listed in the ESX/ESXi 4.x SATP
(Storage Array Type Plug-in) driver
SATP to properly configure failover. Configuring the network manually creates a VMkernel port and maps it
to a physical network interface card (NIC) capable of handling the specific data traffic. Depending on the
number of physical NICs that you use, the networking setup can be different.
NOTE: These steps are not required if you are using ESX/ESXi 5.0.
Connecting a Dell MD3600i-Series or MD Dense iSCSI Storage Array
If using a Dell MD3600i-series or MD Dense iSCSI storage array with ESX/ESXi 4.x, run the following
commands before mapping any virtual disks from the iSCSI storage array to the host.
From the ESX/ESXi console:
#esxcli nmp satp addrule -v DELL -M MD36xxi -s VMW_SATP_LSI
Dell MD Storage Array vCenter Plug-in
are
MD32xx, MD32xxi, MD36xxi or MD36xxf.
.
Therefore, both storage array product IDs must be manually added to the
|