Operating Stove With Burner System; For More Information, Visit Www.desatech.com For More Information, Visit Www.desatech.com - Desa CDVBPC Operation And Installation Manual

Desa owner's operation and installation manual iron stove and direct-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

OPERATING STOVE WITH BURNER SYSTEM

24
LIghting Instructions (Cont.)
To Turn Gas Off To Appliance
Manual Lighting Procedure
Optional Remote Operation
OPERATING STOVE WITH
BURNER SYSTEM
Continued
9.
Push in gas control knob all the way and hold. Immedi-
ately light the pilot by repeatedly depressing the piezo spark
ignitor until a flame appears. Continue to hold for about
one (1) minute after the pilot is lit. Release gas control knob
and it will pop back. Pilot should remain lit. If it goes out,
repeat steps 5 through 8, page 24.
• If gas control knob does not pop up when released, stop and
immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician
or gas supplier.
10. Turn gas control knob counterclockwise
11. Turn on all electric power to the burner system.
12. Turn the ON/OFF switch to ON position.
13. This valve is equipped with a HI/LO feature. Set burner
system input as desired.
14. Close lower panel.
TO TURN OFF GAS
TO APPLIANCE
1.
Open lower panel.
2a. Turn ON/OFF switch to "OFF".
2b. If Using Optional Hand-Held Remote: Set selector switch
in the OFF position to prevent draining battery.
3.
Turn off all electrical power to the appliance if service is to
be performed.
4. Push in gas control knob slightly and turn clockwise
to "OFF".
5.
Close lower panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one
of the following:
1. Turn gas control knob clockwise
position.
2.
Set selector switch in the OFF position.
Variable
Control Knob
Piezo
Ignitor
Figure 56 - Control Valve
For more information, visit www.desatech.com
For more information, visit www.desatech.com
to "ON".
to the PILOT
Gas Control
Knob
MANUAL LIGHTING
PROCEDURE
1. Remove glass door (see Removing/Replacing Glass Door,
page 22).
2.
Follow steps 1 through 8 under Lighting Instructions, page 24.
3. Depress gas control knob and light pilot with match.
4. Keep gas control knob pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release gas control knob. Now
follow steps 10 through 14, column 2.
5. Replace glass door (see Removing/Replacing Glass Door,
page 22).
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must be purchased sepa-
rately (See Accessories on page 39). Follow instructions in-
cluded with the remote control.
Thermostat Control Operation
(Optional CGHRCTA Only) The thermostat control setting on
the remote control unit can be set to any comfort level between
HI and LO. The burners will turn on and off automatically to
maintain the comfort level you select. The ideal comfort setting
will vary by household depending upon the amount of space to
be heated, the output of the central heating system, etc.
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions, page 24.
1. After lighting, let pilot flame burn for about one minute.
Turn gas control knob on the control valve to ON position.
Turn variable control knob anywhere between HI and LO.
Slide the selector switch to the REMOTE position. Note:
The burners may light if hand-held remote ON button was
on when selector switch was last turned off. You can now
turn the burners on and off with either optional hand-held
remote control unit.
IMPORTANT: Do not leave the selector switch in the RE-
MOTE position when the pilot is not lit. This will drain the
battery.
IMPORTANT: Be sure to press the ON/OFF buttons on the
hand-held remote control unit for up to 3 seconds to assure
proper operation.
105501-01F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdvbnc

Table of Contents