High Altitude Installation - Desa CDVBPC Operation And Installation Manual

Desa owner's operation and installation manual iron stove and direct-vent (freestanding fireplace heater) burner system
Table of Contents

Advertisement

VENTING INSTALLATION
Continued
Figure 36 - Vertical Rigid Venting Configuration Using Two 90°
Elbows
Figure 37 - Vertical Rigid Venting Configuration With No
Horizontal Run
For more information, visit www.desatech.com
For more information, visit www.desatech.com
105501-01F
Venting with Two 90° Elbows
Vertical (V
)
Horizontal (H)
1
5' min.
6' max.
6' min.
12' max.
7' min.
18' max.
8' min.
20' max.
Note: Vertical (V
) + Vertical (V
1
20' max.
Note: Install restrictor
into 4" collar of burner
system as shown.
Vertical Venting
V = 40' max.
Note: Install restrictor
into 4" collar of burner
system as shown.
RVKBK Kit Shown
Installation For Vertical Termination (Cont.)
Parts Lists For Venting Kits And Components

HIGH ALTITUDE INSTALLATION

Your Comfort Glow cast iron stove and direct-vent burner system
has been CSA tested and approved for operation at altitudes in the
USA from 0-2000 ft. and in Canada from 0-4500 ft.
When installing this stove at an elevation above 2000 feet (in the
USA), you may need to decrease the input rating by changing the
existing burner orifice to a smaller size. Reduce input 4% for each
) =
1000 feet above sea level. Check with your local gas company for
2
proper orifice size identification.
When installing this stove at an elevation above 4500 feet (in
Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice
for your location
For assistance with any high altitude installation contact DESA
International's Technical Service Department at 1-866-672-6040.
PARTS LISTS FOR VENTING KITS AND
COMPONENTS
Number
Description
P-47-12-K
12" Black Coaxial Pipe (1 pk)
P-47-24-K
24" Black Coaxial Pipe (1 pk)
P-47-48-K
48" Black Coaxial Pipe (1 pk)
PA47-712-K 7"-12" Black Coaxial Pipe (1 pk)
P-47-6-K
6" Black Coaxial Pipe (1 pk)
E47-60-K
60° Elbow (1 pk)
E47-30-K
30° Elbow (1 pk)
E47-90-K
90° Elbow (1 pk)
E47-45-K
45° Elbow (1 pk)
PA-47-6-K
6" Adaptor Collar, Black (1 pk)
WS-47
Wall Strap (1 pk)
SC-47
Storm Collar (1 pk)
VT-47
Vertical Round Termination (1 pk)
WF-47
Wall Firestop (1 pk)
VR-47
Vertical Restrictor (1 pk)
FP-47
Firestop Plate (1 pk)
HTS-47
Horizontal Square Termination (1 pk)
CS-47
Cathedral Ceiling Support Box (1 pk)
RF-47-6
Roof Flashing 0 to 6/12 Pitch (1 pk)
RF-47-12
Roof Flashing 6/12 to 12/12 Pitch (1 pk)
S-47
Vinyl Siding Standoff (1 pk)
TP-47
Trim Plate, Black (1 pk)
HT-47
Horizontal Round Termination (1 pk)
ST-47-14
14" Snorkel Termination (1 pk)
ST-47-36
36" Snorkel Termination (1 pk)
VENTING INSTALLATION
High Altitude Installation
17
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdvbnc

Table of Contents