Chapter 5
Troubleshooting SAN Switching Issues
S e n d d o c u m e n t c o m m e n t s t o n e x u s 5 k - d o c f e e d b a c k @ c i s c o . c o m .
version 5.0(1a)
interface fc1/1
switchport rate-mode dedicated
switchport mode E
switchport trunk allowed vsan 100
no shutdown
switch(config-if)# interface fc 2/3
switch(config-if)# switchport trunk allowed vsan
add
switch(config-if)# switchport trunk allowed vsan add 100
switch(config-if)# show run interface fc 2/3
!Command: show running-config interface fc2/3
!Time: Wed Aug
version 4.2(1)N1(1)
interface fc2/3
switchport mode E
switchport trunk allowed vsan 1
switchport trunk allowed vsan add 100
no shutdown
switch(config-if)# switchport trunk allowed vsan add 1
switch(config-if)# show run interface fc 1/1
!Command: show running-config interface fc1/1
!Time: Wed Aug
version 5.0(1a)
interface fc1/1
switchport rate-mode dedicated
switchport mode E
switchport trunk allowed vsan 1
switchport trunk allowed vsan add 100
no shutdown
fc2/3 is trunking
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:43:00:0d:ec:da:6e:00
Peer port WWN is 20:01:00:0d:ec:24:5b:c0
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port mode is TE
Port vsan is 1
Speed is 4 Gbps
Transmit B2B Credit is 250
Receive B2B Credit is 16
Receive data field Size is 2112
Beacon is turned off
Trunk vsans (admin allowed and active) (1,100)
Trunk vsans (up)
Trunk vsans (isolated)
Trunk vsans (initializing)
switch(config-if)# show interface brief
-------------------------------------------------------------------------------
Interface
OL-25300-01
all
4 16:07:25 2010
4 16:20:54 2010
Vsan
Admin
Admin
Mode
Trunk
(1,100)
()
()
Status
SFP
Cisco Nexus 5000 Series Troubleshooting Guide
Oper
Oper
Port
Mode
Speed
Channel
VSANs
5-43