Destination IP address:
For each number enter the corresponding IP address for the desired remote sta-
tion.
Destination password:
If the remote station is password protected, enter the password here.
You can save up to ten target IP-addresses on this page. This means that also
only ten passwords for connections can be defined here. If more than ten con-
nections are necessary, for example when connections are initiated by a control-
ling system, such as VIDOS or Bosch Video Management System, you can
define a general password. The VIP X2 can make connections with this general
password to all devices protected by that same password. In such cases, pro-
ceed as follows:
– Select 10 in the Number of destination IP address list box.
– Enter 0.0.0.0 in the Destination IP address field.
– Enter the password in the Destination password field.
– Set the user password of all the devices to be connected to this password.
Note
Setting target 10 to the destination IP address 0.0.0.0 will override its func-
tion as the tenth address to try for auto-connect on alarm. Instead the pa-
rameter is used only to store the general password.
Remote port:
Choose the browser-port, depending on the network configuration. Port 443 for
HTTPS connections is only available if the On option in SSL encryption is
active.