Bosch VIPX2 Installation And Operating Manual page 119

Operation manual
Table of Contents

Advertisement

VIP X2 | Installation and Operating Manual
Connect on alarm
With the appropriate configuration, a connection between a sender and a
receiver is made automatically when an alarm is triggered (see page 70).
After a short time the live video image from the sender appears on the con-
nected monitor.
This option can also be used to connect a sender and a compatible receiver
using a switch connected to the alarm input. You do not need a computer to
make the connection in this case.
Connecting with a terminal program
Various requirements must be met in order to operate with a terminal program
(see page 129).
– Start the terminal program and enter the command 1 in the main menu to
switch to the IP menu.
– Enter the command 4 in the IP menu to change the remote IP address, then
enter the IP address of the unit you wish to connect to.
– Return to the main menu by entering the command 0. Then enter the com-
mand 4 to switch to the Rcp+ menu.
– In the Rcp+ menu, enter the command 5 to activate the automatic connec-
tion.
Closing the connection with a terminal program
– Start the terminal program (see page 129) and enter the command 4 in the
main menu to switch to the Rcp+ menu.
– In the Rcp+ menu, enter the command 5 to deactivate the automatic connec-
tion.
Bosch Security Systems | 2006-12 | V2.5
EN | 119
Operation

Advertisement

Table of Contents
loading

Table of Contents