Download Print this page

Delta AC Motor Drives VFD-XXXE Getting Started Manual page 13

Delta electronics ac motor drives quick start manual

Advertisement

Pr.
Explanation
Delay Time at 10Hz
01.21
for Simple Position
Delay Time at 20Hz
01.22
for Simple Position
Delay Time at 30Hz
01.23
for Simple Position
Delay Time at 40Hz
01.24
for Simple Position
Delay Time at 50Hz
01.25
for Simple Position
Maximum Voltage
01.26
Frequency (Fbase)
(Motor 1)
Maximum Output
01.27
Voltage (Vmax)
(Motor 1)
Mid-Point
01.28
Frequency (Fmid)
(Motor 1)
Mid-Point Voltage
01.29
(Vmid) (Motor 1)
Minimum Output
01.30
Frequency (Fmin)
(Motor 1)
Minimum Output
01.31
Voltage (Vmin)
(Motor 1)
Maximum Voltage
01.32
Frequency (Fbase)
(Motor 2)
Maximum Output
01.33
Voltage (Vmax)
(Motor 2)
Mid-Point
01.34
Frequency (Fmid)
(Motor 2)
Mid-Point Voltage
01.35
(Vmid) (Motor 2)
Minimum Output
01.36
Frequency (Fmin)
(Motor 2)
Minimum Output
01.37
Voltage (Vmin)
(Motor 2)
Maximum Voltage
01.38
Frequency (Fbase)
(Motor 3)
Maximum Output
01.39
Voltage (Vmax)
(Motor 3)
Settings
0.00 to 600.00 sec
0.00 to 600.00 sec
0.00 to 600.00 sec
0.00 to 600.00 sec
0.00 to 600.00 sec
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
English- 13
Factory
NOTE
Setting
0.00
0.00
0.00
0.00
0.00
60.00
220.0
440.0
1.50
10.0
20.0
1.50
10.0
20.0
60.00
220.0
440.0
1.50
10.0
20.0
1.50
10.0
20.0
60.00
220.0
440.0

Advertisement